Tenants press the button upstairs, the intercom buzzes, and the lobby door stays locked. In most buildings the fault is in the electric strike, its power supply or the wiring between them, and it is usually fixable the same day.
Tell us what's happening and we'll call you back fast. Photos of the strike and intercom panel help.
No obligation. We reply quickly, 24/7.
A buzz-in entry has four parts that all have to work at the same moment: the intercom or suite phone, a relay that sends power, a power supply, and the electric strike in the door frame. When any one of them fails, the door stays locked and people end up waiting outside or propping it open.
We get this call every week from small walk-up buildings, condo lobbies and offices across Toronto. The story is almost always the same. The buzzer used to work, then it started working "sometimes", and now nobody can get in unless someone comes down to open the door by hand. Couriers leave, visitors call from the sidewalk, and eventually a tenant wedges the door with a folded flyer. That last part is the real problem: a propped entry door is a security gap for the whole building.
The good news is that most buzz-in failures are not a sign that the entire intercom system has to be replaced. In our experience the most common causes are a strike that has worn out, a keeper that is binding because the door has sagged, a tired power supply, or a loose connection in the wiring. Those are repairs, not renovations. A trained technician with a multimeter can usually tell within the first visit which part has failed and whether it makes sense to fix or replace it.
This guide walks through how the system works, the eight problems we find most often, what a property manager or owner can safely check before calling, and when it is time for a professional. If you would rather skip the reading, call 647-951-3510 and describe what you hear when someone presses the buzzer. That one detail tells us a lot.
If the handset still buzzes when a visitor presses the button, the calling side works. The fault is more often downstream: relay, power, wiring or the strike itself.
A strike can release perfectly and still not let the door open if the latch is pressing hard against the keeper. A sagging door or a strong door closer can cause this.
A door that never locks is worse than one that never opens. If the strike is stuck in the unlocked position, treat it as urgent and book an emergency visit.
These are the faults we find most often on buzz-in doors in Toronto apartment buildings, condos and commercial units. Some you can check yourself. Most need a technician with the right parts and a meter.
The strike clicks, but the door will not push open. The latch is jammed against the keeper because the door has dropped, the weatherstrip is too thick, or the closer is pulling the door tight.
No click at all at the door, even though the buzzer upstairs sounds normal. Strikes that are powered for long periods, or fed the wrong voltage, eventually burn out their coil.
The strike only hums weakly, works in the morning but not at night, or works for one suite and not another. An aging transformer often cannot deliver enough current under load.
Wires running from the panel to the strike pass through a hollow metal frame. They get pinched by screws, chewed by vibration, or corroded where water gets in near the threshold.
The intercom rings the suite, but pressing "door" on the handset does nothing. The small relay that closes the strike circuit inside the panel may have worn out.
A previous installer used a strike that does not match the lock, the frame or the voltage. It may have worked for a while, but it was never going to last.
Dirt, old paint or winter ice in the keeper stops it from swinging even when the solenoid releases. Very common on exterior entrances after a freeze.
Someone pried the door or kicked it. The strike is bent, the frame is spread, or the keeper no longer lines up with the latch.
Understanding the chain makes it much easier to describe the problem on the phone, and much easier to understand a quote.
The visitor presses a button or dials a code on the entry panel. The panel rings the suite handset, phone or app.
The suite sends a signal back to the panel. A relay in the panel closes and connects power to the strike circuit for a few seconds.
A transformer or DC power supply sends the correct voltage down the wires to the strike in the door frame.
The strike's solenoid pulls a pin, the keeper is free to swing, and the latch can pass through when the door is pushed.
The visitor pulls or pushes the door. The latch clears the keeper, as long as it is not pressing hard against it.
Power drops, the keeper locks again, and the closer brings the door back so the latch catches.
Not every failure means a new strike. Here is how we decide on site.
This is the question that matters most for safety and for code. Choosing the wrong mode can leave a building open during a power outage, or break fire rules.
Stays locked from the outside when power is off. Power releases it. This is the normal choice for apartment and condo entrances, and it keeps the building secure in a blackout. People can still leave from inside using the lever or push bar.
Unlocks when power is off. Power keeps it locked. It is used in some interior and access-controlled doors, but on an exterior entrance it means the building is open during every power cut.
A fire door has to stay latched during a fire, so any strike on it must be a fire-rated, fail-secure model. If your strike is on a fire door, read our fire-rated door code guide first.
Inside the building, egress should never depend on the strike. The strike only controls entry from the outside. Anyone inside must be able to leave with a single motion on the lever or panic bar, with no key and no button. If your door has been set up so people need to press something to get out, call us so we can review it, because that is a safety problem, not just an inconvenience.
We test before we replace. That keeps the bill honest and makes sure the door actually works when we leave.
We buzz from a suite and watch the door. Click, hum or silence each point to a different part of the system.
Hinges, closer, latch and keeper alignment. A lot of "electrical" problems are mechanical.
Voltage at the supply, at the panel output and at the strike terminals, under load.
If power is lost between the panel and the strike, we find where and repair that section.
We explain what failed and why, then fix it with the correct strike type, voltage and mode.
We test multiple times before we leave, and the work is covered by our warranty.
A buzz-in door is only as reliable as the door it is mounted on. We handle the whole entrance.
Diagnosis, replacement and new installs on metal, aluminum and wood frames.
Maglock repair and installation for offices and access-controlled doors.
Fob, keypad and card-reader doors that won't unlock or won't relock.
Aluminum and glass entrance doors, hinges, pivots and hardware.
Sagging, bent or damaged hollow metal doors and frames.
Fire-rated hardware, panic bars and self-closing exit doors.
Building entrances, lobby doors and commercial entries across the GTA.
Every building is wired differently, so we quote after we test. These are the four levels of work we see, from simplest to most involved.
Keeper realignment, hinge shimming, closer tension, clearing debris. The strike itself is fine.
Loose terminals, a failed transformer or a damaged wire section between panel and strike.
New strike body matched to the lock, frame and voltage, including any frame prep.
New strike plus power supply, new wiring run, or conversion to fob or keypad entry.
For typical commercial door pricing see our commercial door repair cost guide, or request a free estimate with a photo of your strike and panel.
Same-day and after-hours service across Toronto and the GTA.
Five minutes of checking before you call saves time on site and gets the door working faster.
Sometimes the strike is fine and the real issue is the door. A heavy lobby door with a worn closer slams and pushes the latch hard into the keeper. A damaged frame can shift the keeper out of line. Worn pivots or hinges let the door drop at the latch side. On glass entrances, a failing floor pivot does the same. We look at the whole door, because a new strike on a door that is out of alignment will fail again.
If your building uses magnetic locks instead of a strike, the symptoms and fixes are different. Our maglock and electric strike troubleshooting guide compares the two. For buildings planning a bigger change, see our notes on condo door replacement rules in Toronto and barrier-free door requirements, which often come up when an entrance gets a push-button opener at the same time.
For houses and small multiplexes with a single front door, a front door security upgrade or a smart lock is often simpler than a full buzz-in system. And if the whole entrance is tired, a repair vs replacement assessment can save money in the long run.
The calling side of the intercom works, but the release side does not. The most common causes are latch pressure on the keeper, a dead strike coil, a weak power supply or a broken wire. A quick test with a meter tells which one.
If pushing the door toward the frame and then opening it works, the strike is releasing and the door is binding on the keeper. That is usually an alignment or closer adjustment, not a new strike.
We do not recommend it. An entrance that never locks gives anyone access to the building. Call for same-day or emergency service instead.
Yes. Most apartment intercoms, including Commax and similar brands, drive a standard electric strike through a relay output. We work on the strike, power and wiring side of the system and check the panel output during diagnosis.
Fail-secure stays locked when power is lost. Fail-safe unlocks when power is lost. Most building entrances should be fail-secure, and fire-rated doors must use fire-rated, fail-secure strikes.
Yes. The strike only controls entry from outside. Exit from inside should always work with the lever or push bar, with no key needed.
Adjustments and wiring repairs are often done in a single visit. A replacement strike may need frame preparation, which adds time, but most jobs are finished the same day.
We serve Toronto and the GTA, including North York, Scarborough, Etobicoke, Mississauga, Vaughan, Markham, Richmond Hill and Brampton. See the list of cities below.
Local service pages for electric strike installation and repair in your area.
Whether it is a three-unit walk-up or a busy condo lobby, we will find the fault and fix it properly. Licensed, insured and backed by a warranty on every job.
📞 Call 647-951-3510 Request a Free EstimateRead what our clients say · General FAQ · Common door problems in the GTA